40/60 kW all-in-one single-gun DC charging pile
- Product Description
-
Technical Specifications
Power rating
40KW
60KW
Input voltage
304 - 465VAC
304 - 465VAC
Input frequency
45 - 65 Hz
45 - 65 Hz
Output voltage
50 - 1000V DC
50 - 1000V DC
Output power
40KW
60KW
Maximum current
DC80A
DC125A
Gun cable length
5M
5M
System efficiency
≥96%
≥96%
Protection rating
IP54
IP54
Power factor
≥0.99
≥0.99
Standard
CCS1, CCS2, GB/T, CHAdeMo
Auxiliary power supply
12V
12V
Startup method
Scan the code, enter the VIN, and use a password to charge.
Scan the code, enter the VIN, and use a password to charge.
Communication interface
4G, Ethernet
4G, Ethernet
Cooling method
Fan cooling
Fan cooling
Operating temperature
-30℃ - 55℃
-30℃ - 55℃
Relative humidity
5% - 95% non-condensing
5% - 95% non-condensing
Operating altitude
≤2000m
≤2000m
Protection function
Overvoltage protection, undervoltage protection, overload protection, short-circuit protection, ground-fault protection, surge protection, and leakage protection.
Overall dimensions
W×D×H 500×300×500mm
W×D×H 500×300×500mm
Charging Station Installation Process
The concrete grade shall be no lower than C20; the underground portion shall have a height of at least 400 mm, and the above-ground portion at least 200 mm. The concrete foundation dimensions are 300 mm by 200 mm, with an intact, smooth surface free of cracks.
Cable Installation
Charging pile power
Recommended cable (copper) model mm²
Recommended cable (aluminum) model mm²
40 kW single-gun integrated charging station
YJV-3*25+2*16
YJV-3*35+2*16
60 kW single-gun integrated charging station
YJV-3*50+2*35
YJV-3*70+2*35
>>The AC input cable shall be routed starting from the user’s distribution switch and connected to the switch’s output terminals just before energization.
>>The distribution panel shall be equipped with protective devices against overcurrent, short circuits, lightning strikes, and other hazards.
>> On AC power lines, the colors yellow, green, red, and light blue correspond respectively to the AC phases A, B, C, and the neutral wire.
>> If the power cable is of a single color, a wire‑number label must be affixed (or a marked sleeve must be fitted).
>> AC power lines shall be routed separately from DC lines.
>> Power lines must not have any breaks, damage, or scratches.
The typical wiring sequence is: first the protective earth, then the neutral conductor, and finally the AC phase conductors.
>> Before making electrical connections, ensure that all switches, fuses, and other devices are in the open position.