240kW All-in-One Four-Outlet DC Charging Pile
- Product Description
-
Technical Specifications
Power rating
240KW
Input voltage
260 - 530 VAC
Input frequency
45 - 65 Hz
Output voltage
50 - 1000 VDC
Output power
240KW
Maximum current
DC250A+DC250A
Gun cable length
5M
System efficiency
≥96%
Protection Level
IP54
Power factor
≥0.99
Standard
CCS1, CCS2, GB/T, CHAdeMo
Auxiliary power supply
12V, 24V (optional)
Startup Method
Scan the code, VIN, or password to charge.
Communication Interface
4G, Ethernet
Cooling method
Fan cooling
Operating temperature
-30℃~55℃
Relative humidity
5%–95% non-condensing
Working Altitude
≤2000m
Protection function
Overvoltage protection, undervoltage protection, overload protection, short-circuit protection, ground fault protection, surge protection, and leakage current protection.
Overall dimensions
W×D×H 800×630×1800mm
Charging Pile Installation Process
>> The concrete grade shall be no lower than C20; the underground portion shall have a height of no less than 400 mm, and the above-ground portion no less than 200 mm; the concrete foundation dimensions shall be 800 mm × 700 mm (length × width); the surface shall be intact, smooth, and free of cracks. See the detailed external appearance below:
Cable Installation
Charging pile power
Recommended cable (copper) model mm²
Recommended cable (aluminum) model mm²
240kW Dual-Connector Integrated Charging Pile
Two YJV-3*95+2*50 cables
Two YJV-3*150+2*95 cables
>> The communication input cable shall be routed starting from the user’s distribution switch and connected to the switch’s output terminals just before energization.
>The distribution room shall be equipped with protection devices against overcurrent, short circuit, and lightning strikes.
>> On AC power lines, the colors yellow, green, red, and light blue correspond to AC phases A, B, C, and the neutral wire, respectively.
>> If the power cable is of a single color, a cable identification label must be affixed (or a labeled sleeve must be fitted).
>> AC power cables shall be routed separately from DC cables.
>> Power lines must not have any breaks, damage, or scratches.
>> The typical wiring sequence is to connect the protective earth first, followed by the neutral, and finally the AC phase conductors.
>> Before making electrical connections, ensure that all switches, fuses, and other protective devices are in the open (off) position.