120/160 kW Integrated Dual-Port DC Charging Pile
- Product Description
-
Technical Specifications
Power rating
120KW
160KW
Input voltage
304 - 456 VAC
304 - 456 VAC
Input frequency
45 - 55 Hz
45 - 65 Hz
Output voltage
50 - 1000 VDC
50 - 1000 VDC
Output power
120KW
160KW
Maximum current
DC250A+DC250A
DC250A+DC250A
Gun cable length
5M
5M
System efficiency
≥96%
≥96%
Protection Level
IP54
IP54
Power factor
≥0.99
≥0.99
Standard
CCS1, CCS2, GB/T, CHAdeMo
Auxiliary power supply
12V
12V
Startup Method
Scan the code, VIN, or password to charge.
Scan the code, VIN, or password to charge.
Communication interface
4G, Ethernet
4G
Cooling method
Fan cooling
Fan cooling
Operating temperature
-30℃ - 55℃
-30℃ - 55℃
Relative humidity
5% - 95% non-condensing
5% - 95% non-condensing
Working Altitude
≤2000m
≤2000m
Protection function
Overvoltage protection, undervoltage protection, overload protection, short-circuit protection, ground fault protection, surge protection, and leakage current protection.
Overall dimensions
W×D×H 700×400×1700mm
W×D×H 750×500×1700mm
Charging Pile Installation Process
>> The concrete grade shall be no lower than C20; the underground portion shall have a height of no less than 400 mm, and the above-ground portion no less than 200 mm. The concrete foundation dimensions shall be 900 mm × 600 mm (length × width), with a complete, smooth, and crack-free surface. See the detailed external appearance below:
Cable Installation
Charging pile power
Recommended cable (copper) model mm²
Recommended cable (aluminum) model mm²
120kW Dual-Connector Integrated Charging Pile
YJV-3*95+2*50
YJV-3*120+2*70
160kW Dual-Connector Integrated Charging Pile
YJV-3*120+2*70
YJV-3*185+2*95
>> The communication input cable shall be routed starting from the user’s distribution switch and connected to the switch’s output terminals just before energization.
>>The distribution room shall be equipped with protection devices for overcurrent, short circuit, and lightning strikes.
>> On AC power lines, the colors yellow, green, red, and light blue correspond to AC phases A, B, C, and the neutral wire, respectively.
>> If the power cable is of a single color, a wire identification label must be affixed (or a marked sleeve must be fitted).
>> AC power cables shall be routed separately from DC cables.
>> Power lines must not have any breaks, damage, or scratches.
>> The typical wiring sequence is to connect the protective earth first, followed by the neutral, and finally the AC phase conductors.
>> Before making electrical connections, ensure that all switches, fuses, and other protective devices are in the open (off) position.